Replace toggle switch, if it is not functional (WP 0040).

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  65    66    67    68    69  70  71    72    73    74    75  
img
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
0012
TM 10-4930-369-13&P
FIELD MAINTENANCE
MAINTAINER TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Tools and Special Tools
Personnel Required
GMTK (WP 0063), Item 7)
Quartermaster and Chemical Equipment
Repairer 91J - 2
Materials/Parts
References
Apron, Rubber (WP 0062, Item 1)
Extinguisher, Fire (WP 0061)
WP 0015
Gloves, Chemical/Oil Protective (WP 0062, Item 10)
WP 0023
Goggles, Industrial (WP 0062, Item 13)
WP 0024
Pail, Utility, 5 Quart (WP 0062, Item 16)
WP 0026
Pan, Drain, 5 gal cap (WP 0063, Item 6)
WP 0033
Rag, Wiping (WP 0062, Item 18)
WP 0034
Spill Kit (WP 0062, Item 20)
WP 0035
Tag, ShippingWP 0062, Item 22)
WP 0036
Wire Marker Book (WP 0062, Item 24)
WP 0040
Table 1 provides symptom based troubleshooting procedures necessary to diagnose malfunctions for the FDS.
The troubleshooting procedures may not correct all malfunctions encountered. However, the procedures provide a
step-by-step approach that directs tests and inspections toward the source of a problem. Each troubleshooting
procedure lists a description of possible causes followed by a step or sequence of steps to check the operation of a
component.
Always irst perform a visual and physical inspection of the suspected unserviceable items. Look for obvious signs
of damage such as loose or broken parts, discoloration, and bad connections.
TROUBLESHOOTING PROCEDURE
SYMPTOM
FDS does not operate when toggle switch is set to ON.
MALFUNCTION
110/120 VAC source power is not available.
CORRECTIVE ACTION
STEP 1.
Unplug FDS from source power.
STEP 2.
Test for 110/120 VAC voltage at source power receptacle.
STEP 3.
Establish 110/120 VAC source power.
MALFUNCTION
Power plug or power cable is defective.
CORRECTIVE ACTION
STEP 1.
Remove toggle switch box cover and access toggle switch wiring (WP 0040), (WP 0024).
STEP 2.
Tag and disconnect wiring from switch.
STEP 3.
Check continuity on hot, neutral and ground circuit between plug and toggle switch box (WP 0040).
STEP 4.
Check for shorts between hot, neutral, and ground (WP 0040).
STEP 5.
Replace defective power plug (WP 0023), or repair power cable (WP 0024).
MALFUNCTION
Toggle switch is defective.
CORRECTIVE ACTION
STEP 1.  Test toggle switch for proper function - continuity (ON) and open (OFF). Check for shorts between hot,
neutral, and ground (WP 0040).