OPERATOR\CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) INTRODUCTION
OPERATOR\CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  70    71    72    73    74  75  76    77    78    79    80  
img
. . . . . . . . . . .
0014
TM 10-4930-369-13&P
OPERATOR INSTRUCTIONS
OPERATOR\CREW PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INITIAL SETUP:
Materials/Parts
Personnel Required
Petroleum Supply Specialist 92F
Apron, Rubber (WP 0062, Item 1)
Extinguisher, Fire (WP 0061)
References
Gloves, Chemical/Oil Protective (WP 0062, Item 10)
WP 0016
Goggles, Industrial (WP 0062, Item 13)
Pail, Utility, 5 Quart (WP 0062, Item 16)
Equipment Condition
Pan, Drain, 5 gal cap (WP 0063, Item 6)
FDS disconnected from power source (WP 0005)
Rag, Wiping (WP 0062, Item 18)
Spill Kit (WP 0062, Item 20)
Table 1. Operator/Crew PMCS For FDS -- Before.
EQUIPMENT
ITEM TO BE
ITEM
INTERVAL
NOT READY/
CHECKED OR
NO.
PROCEDURE
AVAILABLE IF:
SERVICED
1
Before
Cargo
1.
Check cargo container for damage.
Cargo container
Container
(Figure 1, Item
1), is loose or
damaged beyond
use.
Figure 1. Cargo Container.
2
Cable or plug is
Before
Power Cable
1.
Check for fraying or cracks on power
damaged beyond
and Plug
cable (Figure 2, Item 1), cracks or
use.
broken plug (Figure 2, Item 2).
Figure 2. Power Cable and Plug.
Pump or pump
3
Pump
Before
1.
Check for loose, missing or damaged
drain assembly
parts, dust plug, cam-locking ittings,
visibly damaged.
drain assembly.
4
Switch does not
Before
Toggle Switch
1.
Check for proper operation of the toggle
operate correctly.
switch. Switch should move ON and
OFF with an audible and felt click
00141