Measure resistance between the ground clips
Figure 2. Ground Wire Loop Attached to Ground Clip.

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  165    166    167    168    169  170  171    172    173    174    175  
img
. . . .
0032
TM 10-4930-369-13&P
FIELD MAINTENANCE
REPAIR GROUNDING REEL
INITIAL SETUP:
Tools and Special Tools
Equipment Condition
GMTK (WP 0063, Item 7)
FDS disconnected from power source (WP 0005)
Materials/Parts
Gloves, Leather Work (WP 0062, Item 12)
Personnel Required
Quartermaster and Chemical Equipment
Repairer 91J
WARNING
Maintenance must not be performed on equipment that is operating. Failure to comply may
result in injury or death to personnel.
REPAIR
Remove Grounding Reel Clip
1.  Remove the screw (Figure 1, Item 2) and stamped nut (Figure 1, Item 4) from the clip (Figure 1, Item 3).
Retain fasteners.
2.  Separate clip (Figure 1, Item 3) from ground wire loop (Figure 1, Item 1).
Figure 1.
Ground Clip.
Install Grounding Reel Clip
NOTE
Ground clip is threaded for machine screw. The stamped nut acts as a jam nut.