Figure 14. Remove Wire Nuts and Cable.
Figure 18. Insertion of Cable through Gland into Housing.

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  111    112    113    114    115  116  117    118    119    120    121  
img
0024
TM 10-4930-369-13&P
Figure 16. Pump Motor Electrical Enclosure.
9.
Remove electrical tape (if present) and wire nuts (Figure 16, Item 4) from remaining wires (Figure 16, Item 5)
in pump motor electrical enclosure (Figure 16, Item 2).
10. Pull power cable (Figure 16, Item 1) from pump motor electrical enclosure (Figure 16, Item 2).
11. Cut any tie down straps (Figure 17, Item 1) to free cable from frame.
Figure 17. Cut Tie Down Straps.
002410