0024
TM 10-4930-369-13&P
4.
Wipe switch cover and switch enclosure mating surfaces of any conductive grease or corrosion preventive
compound.
5.
Remove electrical tape (if present) and wire nuts (Figure 14, Item 3) from the remaining wires (silver/neutral
and green/ground) in switch enclosure (Figure 14, Item 1). Loosen ground screw (Figure 14, Item 2) and
remove ground wires from ground screw.
Figure 14. Remove Wire Nuts and Cable.
6.
Pull cable (Figure 14, Item 4) down and out from switch enclosure (Figure 14, Item 1).
7.
Loosen cable gland nut (Figure 15, Item 1) on pump motor electrical enclosure.
Figure 15.
Loosen Gland Nut.
8.
Remove cap (Figure 16, Item 3) from electrical enclosure (Figure 16, Item 2). Push cable (Figure 16, Item 1)
from gland side towards housing until wires (Figure 16, Item 5) protrude from housing (Figure 16, Item 2).
00249