Section 1 - Cable (Power Plug to Toggle Switch) Installation
Figure 8. Corrosion Preventive Compound on Cover Flange.

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  106    107    108    109    110  111  112    113    114    115    116  
img
0024
TM 10-4930-369-13&P
3.
Insert wire-ends of cable (Figure 6, Item 5) through gland nut (Figure 6, Item 1) and gland (Figure 6, Item 2) on
top of switch enclosure (Figure 6, Item 3). Feed cable through gland until outer cable jacket (Figure 6, Item
4) is visible within enclosure.
Figure 6. Cable Inserted Into Gland Nuts.
4.
Using toggle switch wiring diagram (Figure 7), reconnect white/neutral and green/ground wiring within switch
enclosure using wire nuts and electrical tape.
Figure 7. Toggle Switch Wiring Diagram.