Figure 4. Differential Pressure Gauge.
Figure 6. Self-Priming Pump Intake Valve.

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
img
0004
TM 10-4930-369-13&P
Figure 5.
Fuel Nozzle Lever.
Table 5. Fuel Nozzle Lever.
KEY
CONTROL/INDICATOR
FUNCTION
1
Fuel Nozzle Lever
A three-position lever that controls the rate of fuel low at the receiving
equipment. OFF: Flow stopped. The lever is fully extended from the
handle. Low Flow Rate: The lever is resting on the middle notch. High
Flow Rate: The lever is resting on the notch nearest the handle.