REPAIR PUMP
Clean and Inspect Pump Inlet

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  141    142    143    144    145  146  147    148    149    150    151  
img
0027
TM 10-4930-369-13&P
1.
Remove dust plug (Figure 1, Item 4) from pump inlet cam-locking coupling half (Figure 1, Item 1).
Figure 1.
Pump Inlet.
2.
Using suitable container, disconnect pump inlet cam-locking coupling half from suction hose by performing
the following:
1. Release cam-locking levers (Figure 1, Item 2) on pump inlet cam-locking coupling half (Figure 1, Item 1).
2. Pull suction hose (Figure 1, Item 5) from pump inlet cam-locking coupling half (Figure 1, Item 1).
3.  Remove gasket (Figure 1, Item 3) from pump inlet cam-locking coupling half (Figure 1, Item 1). Discard
gasket (Figure 1, Item 3).