Remove 1/4 in. drain tube (Figure 4, Item 4) from pump drain (Figure 4, Item 3).
Figure 4.
Pump.
9. Remove four lange bolts, nuts and lock washers (Figure 4, Item 1). Discard lock washers.
10. Remove four hex head cap screws, lat washers and lock washers from pump mount (Figure 4, Item 2).
Discard lock washers.
00265