Figure 6-5. Generator regulator cutout relay adjustment.
are properly lined up and tighten the screws well after
contact screw.
The most convenient method of
adjustment.
performing this operation is to insert the gauge, press
the armature down against it to hold it in place, and then
turn the contact screw until the contacts barely touch.
(3) With the battery disconnected, refer to
(5) Connect the generator regulator and
inch by bending the upper armature stop.
generator in a circuit as shown in figure 6-6 and check
the cutout relay (circuit breaker) opening and closing.
(4) Refer to figure 6-4 and check the air gap
With the field rheostat set at maximum resistance, start
of the voltage regulator unit and current regulator unit.
the engine and operate it at 2250 rpm. Adjust the field
The air gap should be measured between the armature
rheostat while watching the voltmeter. Check the
and the part of the core (not the residual pin in the core)
closing voltage of the cutout relay contacts. It must be
next to the residual pin, with the points just touching.
25 to 27 volts as indicated on the voltmeter. Refer to
Measure the air gap by pushing the armature down until
the points open, release until the points barely close,
then measure the air gap. Do not measure the gap with
(6) Connect the generator regulator and
the fiat spring that supports the contact screw raised up
generator in a circuit as shown in figure 6-6 and check
off the fiber mounting plate. Adjust the air gap to .087
the voltage regulator operating volt
inch by loosening the locknut and turning 6-6 the
6-6
|