MEC 4320-240-15/3-20
Figure 3-20. Generator-exploded view.
3-43. Generator
a. General. The generator is rated at 24 volts, 18
generator.
amperes DC (direct current). It is driven by a V-belt
from the water pump pulley. Periodic checks of the
e. Cleaning and Inspection.
generator prevent unnecessary repairs.
(1) Clean the outside of the generator with a cloth
b.
Inspection.
Check generator for tight
dampened with cleaning solvent; wipe dry. Take care
connections and well insulated wiring. Inspect mounting
that no cleaning solvent enters the generator or comes
bolts and belt tension ( inch deflection between
in contact with wires or electrical parts. Clean all other
pulleys).
metal parts in cleaning solvent. Dry with clean, dry
compressed air.
c. Test. Start pumping unit and permit engine to
warm up. Check ammeter (2, fig. 2-4) if it shows
discharge check electrical system further.
3-18
|