b. Service. Check electrolyte level frequently.
3-41. General
Add distilled or drinking water to raise liquid to indicated
level above separators. Add water only while batteries
The electrical system is a 24 volt negative ground
are being charged or pumping unit is operating to mix
system consisting of batteries, generator, generator
solution.
regulator, and magneto.
c. Testing. Check the specific gravity of each cell
3-42. Batteries
with a battery hydrometer. The specific gravity of each
cell must be at least 1.260.
a. General. The unit is powered by two 12 volt
storage batteries, connected in series and contained in a
battery box located at the front of the pumping unit.
the batteries.
Quick-release connectors are provided on the battery
cables.
MEC 4320-240-15/3-19
Figure 3-19. Generator removal and installation.
3-17
|