Section IV. MAINTENANCE PROCEDURES
3-9. General
This section describes the maintenance procedures
assigned to the operator/crew level. Follow instructions
given herein when performing the required maintenance
procedures.
3-10. Air Cleaner Service
NOTE
The air cleaner element must be
replaced after one year of service or
after it has been cleaned six times,
whichever comes first.
a. Removal.
(1) Stop the engine (para 2-5).
(2) Loosen the wing bolt on the clamp assembly (2,
fig. 3-5) and remove the assembled dust cup (3) and
flexible baffle (4). Remove the baffle from the dust cup
and empty the dust from the dust cup.
1.
Precleaner
5.
Wing nut
2.
Clamp assembly
6.
Washer gasket
3.
Dust cup
7.
Air cleaner element
4.
Flexible baffle
8.
Air cleaner body
Figure 3-5. Air cleaner, exploded view.