TM  55-2915-335-30&P 2-11.  PUMP  CANISTER  -  lNSPECT/REPLACE  (Cont) 2-11 b. c. Locking compound was used to secure machine screws (1) in housing. Use wire brush to clean locking compound residue from screw threads. Do not use glass or metal tools to scrape dirt or locking compound from pump housing surfaces. Scraping with metal or glass will destroy the thin, protective coat- ing on the housing. This could lead to leaks or early failure of the pump. Clean packing groove in pump housing using a non-woven  cleaning  cloth  dipped  in  dry  cleaning solvent. Remove all deposits from packing groove. If any scraping is required, do not use metal scrapers. Use only plastic or wood to scrape pump housing  surfaces. GO TO NEXT PAGE 2-26