CAUTION
TM 5-4930-237-10
(16)
Connect one elbow connector (14) to each 2 inch discharge hose (11).
(16)
Remove carrying straps (7) from four 2 inch discharge hoses (11).
(17)
Roll a 2 inch discharge hose (11) out on ground near tee and elbow connectors (8 and 14).
(18)
Remove dust caps (9 and 15) from tee and elbow connectors (8 and 14).
(19)
Remove dust caps (12) from 2 inch discharge hoses (11).
(20)
Connect a 2 inch discharge hose (11) to each tee or elbow connector (8 and 14).
(21)
Connect all dust caps.
d. DELETED
e.
If required, attach adapters (20, 23, 26 or 30) as follows:
(1)
Remove dust cap (15) from 2 inch discharge hone (11).
(2)
Remove dust cap (21, 24, 27, or 31) from adapter (20, 23, 26, or 30).
(3)
Connect from 2 inch discharge hose (11) to adapter (20, 23, 26, or 30).
(4)
Install grounding rod (66) at each refueling point in the system.
f.
Put FLOW handles (2, 6, 10, and 13) in flow position.
2-5.
Connection of CCR Nozzle.
Immediately drain a substantial portion of the fuel from the nozzle whenever the valve on
the hose attached to it is turned to off or the nozzle is removed from the system. The trapped
fuel can create large internal pressure that can damage the nozzle when the temperature rises.
a.
Remove dust cap (15) from 2 inch discharge hose (11).
b.
Connect CCR nozzle (33) to 2 inch discharge hose (11). Refer to TM 5-4930-235-13&P for details.
c.
Haag CCR Nozzle (33) on grounding rod hanger assembly (57).
d.
As required, repeat steps a. and b. for each CCR nozzle (33).
e.
Connect all dust caps.
2-6.
Connection of Overwing Nozzle.
a.
Remove dust cap (36) from overwing nozzle (34).
b.
Remove outlet cap from CCR nozzle (33). Refer to TM 5-4930-235-13&P for details.
2-14
Change 5
|