WARNING
CAUTION
TM 5-4930-237-10
Do not force handle of Dry-Loc connectors to the open position. Damage to the inter-
locking mechanism can result in an inadvertent disconnect and subsequent fuel discharge
during operation. Failure to comply can result in injury or death to personnel or damage
to equipment. If flow handle fails to operate smoothly or hose connectors fail to lock with
flow handle in the open position, refer to table 3-1, Troubleshooting.
Do not throw or drag hose on ground. Do not walk on hose. All flow handles must be facing
up, Failure to comply can result in damage to hose and end connectors. Ground tanker prior
to assembling HTARS system.
Refer to TM 9-2320-279-10-1. operators Manual for HEMTT tanker refueling proce-
dures.
b.
Connect 3 inch discharge hose (1) to suction hose on HEMTT tanker as follows:
(1)
Remove carrying strap (7) from 3 inch discharge hose (1).
(2)
Roll 3 inch discharge hose (1) out Rat and straight on ground behind truck.
(3)
Pull cam arms (4) away from body.
(4)
Slide end over camlock coupling.
(6)
Push cam arms (4) against body.
c.
Connect tee connectors (8), 2 inch discharge hose (11), and elbow connectors (14) as follows:
(1)
Remove dust caps (9) from center of one tee connector (8).
(2)
Connect tee connector (8) to 3 inch discharge how (1).
(3)
Remove carrying straps (7) from two 2 inch discharge hoses (11).
(4)
Roll both 2 inch discharge hoses (11) out flat and straight on ground on each side of tee
connector (8).
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
Remove dust caps (9 end 12) from tee connector (8) and both 2 inch discharge hoses (11).
Connect both 2 inch discharge hoses (11) to tee connector (8).
Remove dust caps (9) from two tee connectors (8).
Cod one tee connector (8) to each 2 inch discharge hose (11).
Remove carrying straps (7) from four 2 inch discharge hoses (11).
Roll 2 inch discharge homes (11) out flat and straight near tee connectors (8).
Remove dust caps (9 and 12) from tee connectors (8) end 2 inch discharge hoses (11).
Connect both 2 inch discharge hoses (11) to tee connectors (8).
Connect 2 inch discharge hoses (11) together.
Remove one dust cap (15) from each elbow connector (14).
Change 3
2-13
|