ORGANIZATIONAL MAINTENANCE INSTRUCTIONS
Section I. SERVICE UPON RECEIPT OF EQUIPMENT
conditions. Normally, water that is suitable for drinking
4-1. General
is suitable for use in the radiator.
Inspection of the received equipment is described
in paragraph 2-1. Service the received equipment as
b. Check the oil level in the engine crankcase,
directed in paragraph 4-2 before putting it into operation.
using the dipstick (8, fig. 4-26). Add oil if the level is
4-2. Servicing
near the low mark on the dipstick.
a. Check the engine coolant.  Make sure the
c. Remove the cover from the battery box (fig. 1-
radiator is filled to the required level and that there is
2). Check that the batteries are properly connected as
sufficient  antifreeze  for  the  required  operating
shown in figure 4-1.  Install the electrolyte in the
batteries as follows:
1.
Cap
5.
Interconnecting cable
2.
Seal
6.
Battery cable
3.
12-volt storage battery
7.
Negative battery terminal
4.
Positive battery terminal
8.
Ground cable
Figure 4-1. Battery box with batteries installed.