Figure 2-6. Stopping Instructions.
2-8. Starting
centrifugal pump.
a. Preparation for Starting.
2-9. Stopping
(1) Perform the necessary daily preventive
Caution
maintenance procedures (para 3-4).
Do not stop the pump by pulling out
(2) If the pump is being started at a new
the choke. This floods the cylinders
installation for the first time or if it has been drained
with raw gasoline, which washes
after the last period of operation, remove the fill plug (6,
away the lubricants and makes the
engine susceptible to wear.
Caution
Always prime the pump before
starting engine. Operating the pump
b. Perform
all
after-operation
preventive
dry may damage the seal.
maintenance services.
(3) Remove the engine cover panels (fig. 1-2).
2-10. Operation Under Usual Conditions
Caution
Prime the pump before starting.
2-7
|