TM 5-4320-234-34
Table 2-1. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE CONTINUED
Figure 2-10. Governor removal.
(9) Install gasket (3, fig. 2-10) and governor (2) on gear cover. Sight through the magto mounting hole to check that the
ne
two marked teeth of the governor drive gear engage the single marked tooth of the cam gear as shown in figure 2-11.
Ignitor timing is dependent upon this relationship because the magneto is driven by the governor drive gear. Install
gasket (12, fig. 2-9), gasket plate (11), flatwasher (10) and bolt (9). Tighten the mounting bolt moderately.
2-13
|