3-17   Install Filter-Separators - Cont'd . 3-17.3 Approximate weight - 375 Ibs.  ea. CAUTION Ground equipment at time of installation. 3-18   Assemble and Install Primary Module Hoselines, Valves and Fittings  . One (1) system per fuel unit/three (3) per TPT. Assemblies  of  the  primary  module  are  crated  in  a  partially  assembled  condition  to  facilitate  packaging  and  shipping. Some  assembly  is  required  to  place  the  units  in  operating  condition  prior  to  installation.    The  following  assembly  and installation procedures are used on the shared berm alternate shown in figure 2-60A.  Procedures for the layout shown in figure 260B or 2-60C will be the same.. 3-18.1 Assembly.  Refer to figure 2-38. a. Position crates containing cross assemblies near their respective installation sites as indicated in figure 2-60A. b. Remove 6-inch aluminum cross assembles, coupling clamps, caps, and coupling gaskets from crate. c. Inspect all items for damage, cleanliness, and quantities required. d. Remove four coupling clamps (3, figure 2-38) securing gate valves (9) and flanged adapters (1) to cross (10). e. Slide one coupling gasket over each cross (10) grooved end. f. Align mating surfaces of adapter (1) and cross (10).  Pull coupling gasket over sealing surfaces of both pieces. Ensure  gasket  is  correctly  positioned  over  full  circumference  of  sealing  surfaces.    Position  coupling  clamp  (3)  over gasket. g. While maintaining alignment of mating parts; lock coupling clamp securely. h. Repeat steps e, thru g.  for remaining adapters(1). 3-18.2 Installation .  Refer to figure 2-60A. CAUTION INTERNAL  CLEANLINESS    Make  sure  all  hoselines,  fittings  and  valves  are  clean  internally. Foreign materials may disrupt operations and damage equipment. a. Check the position of 600 gpm hoseline pump installed per paragraph 3-13. 3-12

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business