| |
TM 10-5430-242-12&P
0005 00
0005 00-11
Change 1
Installation of Filler/Discharge Elbow Assembly
NOTE
The dust cap is attached to the flanged adapter to prevent it from being lost. The
filler/discharge elbow on the discharge end requires a female/male elbow; whereas,
the filler/discharge elbow used on the intake end requires a female/female elbow.
1. Remove dust cap (1) from flanged adapter (2) by pulling cam-lever arms (3) outward and lifting up on
dust cap (1).
2. Inspect elbow (4) for cleanliness.
3. Check that gasket (5) is in place and is properly seated.
4. Position the female end of elbow (4) over flanged adapter (2) with cam-lever arms (6) in the outward
position.
5. Rotate elbow (4) so that the open end points to nearest end of the tank.
NOTE
Cam-lever arms must be pushed inward to lock and pulled outward to unlock the elbow.
6. Lift cam-lever arms (6) and lock elbow (4) in place.
7. Install dust cap (1) on the open end of elbow (4) and lock in place.
1
2
3
4
5
6
|