|
|
TM 10-5430-238-12&P
OPERATOR AND UNIT MAINTENANCE MANUAL
(INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)
COLLAPSIBLE FABRIC TANKS, FUEL STORAGE, 3,000,
10,000, 20,000, AND 50,000 GALLON
DRAIN BALL VALVE (MODELS BA91-141, BA91-140,
PD52983-50, BA91-141A, BA91-140A)
SERVICE, REPLACEMENT, REPAIR
INITIAL SETUP
Tools
Equipment Condition
Tool Kit General Mechanics
Fuel tank drained
(Item 1, WP 0033 00)
Torque Wrench (ft-lb)
(Item 3, WP 0033 00)
Materials/Parts
Mandatory Replacement Parts
Anti-seize Tape
Bonnet gasket
(Item 7, WP 0040 00)
(Item 11, WP 0042 00)
Dry Cleaning Solvent
Stem Seal
(Item 4, WP 0040 00)
(Item 12, WP 0042 00)
Grease
Stem Seal
(Item 5, WP 0040 00)
(Item 13, WP 0042 00)
Rags, Wiping
(Item 6, WP 0040 00)
Thread Sealing Compound
(Item 8, WP 0040 00)
REMOVAL
Remove the drain ball valve from the drain hose assembly.
DISASSEMBLY
1. Remove handle-nut (1) from valve stem (2).
2. Remove handle (3) from valve stem (2).
3. Remove valve stem nut (4) from valve stem (2).
4. Remove travel stop (5), gland ring (6), and valve stem seal (7) from valve stem (2). Discard seal (7).
5. Remove cap screws (8) from bonnet (9). Remove bonnet (9) from valve body (10).
6. Remove valve stem (2), valve stem seal (11), spring (12), bonnet gasket (13), ball (14), and two
ball seats (15) from valve body (10). Discard seal (11) and bonnet gasket (13).
SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially dangerous
to personnel and property. It produces toxic and flammable fumes. Use only
in well ventilated areas. Avoid repeated and prolonged skin contact. Do not
use solvent near an open flame or near excessive heat. The flash point of the
solvent is 100F to 130F (38 C to 59 C).
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
0024 00-1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |