SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially dangerous
to personnel and property. It produces toxic and flammable fumes. Use only
in well ventilated areas. Avoid repeated and prolonged skin contact. Do not
use solvent near an open flame or near excessive heat. The flash point of the
solvent is 100F to 130F (38 C to 59 C).
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
2. Inspect all mechanical parts for cracks, dents, breaks, and wear. Replace the component if
unserviceable.
3. Polish the valve stem with a crocus cloth, then coat the valve stem with grease.
ASSEMBLY
1. Position valve body (8) on its side on a clean surface.
2. Insert wedge disks (9) into valve body (8) slot.
3. Install new packing material (10) into bonnet (6).
4. Insert valve stem (4) into bonnet (6).
5. Install bonnet (6) into valve body (8).
6. Install packing retainer (7) into bonnet (6).
7. Install packing nut (5) onto bonnet (6).
8. Install hand-wheel (2), hand-wheel nut (1), and identification plate (3) on valve stem (4).
INSTALLATION
1. Coat threads (3) of drain hose assembly (2) with thread sealing compound or anti-seize tape.
2. Install drain gate valve (1) on drain hose assembly (2).
END OF WORK PACKAGE