TM 10-5430-237-12&P
0007 00
0007 00-3
CORRECTIVE ACTION
Notify unit maintenance for repair.
SYMPTOM
Tank collar will not deflate.
MALFUNCTION
Check that inflation valve (2) is open.
CORRECTIVE ACTION
Open inflation valve (2) by turning center part of the valve
clockwise (to the right), as stenciled on tank collar (3).
Model WT2008: Check deflation valve is fully open.
CORRECTIVE ACTION
Unscrew deflation valve.
Check inflation valve (2) for damage. Model WT2008, check deflation valve for
damage.
CORRECTIVE ACTION
Notify unit maintenance for repair.
TROUBLESHOOTING PROCEDURE
COVER FLOAT (Models 90074/91038/WT2008)
SYMPTOM
Cover float will not inflate.
MALFUNCTION
Check that inflation valve (4) is open.
CORRECTIVE ACTION
Open inflation valve (4) by turning the center part of the valve
clockwise (to the right), as stenciled on the cover float (5).
Check hand pump (9) for proper operation.
CORRECTIVE ACTION
Replace preformed packing (Item 2, WP 0033 00).
Models 91038 and WT2008, check foot bellows for damage.
CORRECTIVE ACTION
Replace foot bellow if required.
|