TM 10-5430-237-12&P
0007 00
0007 00-2
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check tank collar (3) for tears or punctures.
CORRECTIVE ACTION
Notify unit maintenance for repair.
SYMPTOM
Tank collar deflates after inflation.
NOTE
If temperature has dropped considerably since the collar was inflated, it will appear
to have lost air. Unless it is observed to lose additional air, the collar is in operating
condition and does not have a leak. Do not inflate unless a leak is observed.
MALFUNCTION
Check that inflation valve (2) was fully closed after tank collar (3) was inflated.
CORRECTIVE ACTION
If inflation valve (2) was not fully closed, reinflate the tank collar
(3) to proper psi of approximately 0.5 psi (3.4 kPa), making sure
to properly close valve after inflation by turning counterclockwise
(to the left).
Model WT2008: Check that deflation valve is fully closed.
CORRECTIVE ACTION
Close deflation valve.
Check inflation valves (2) for air leakage.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Model WT2008: Check deflation valve for leaks.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check automotive valve (1) for air leakage.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check tank collar (3) for cuts or punctures.
|