TM 10-5430-237-12&P
0007 00
0007 00-1
OPERATOR AND UNIT MAINTENANCE
COLLAPSIBLE FABRIC TANK, WATER STORAGE, 3000 GALLONS
TROUBLESHOOTING PROCEDURES
INTRODUCTION TO TROUBLESHOOTING.
The Troubleshooting Malfunctions list the common malfunctions which you may find during the operation
or maintenance of the collapsible fabric water tank assembly or its components. Perform the
tests/inspections and corrective actions in the order listed in the table.
This manual cannot list all malfunctions that may occur, nor all tests or inspections and corrective actions.
If a malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.
TROUBLESHOOTING PROCEDURE
TANK COLLAR (Models 90074/91038/WT2008)
SYMPTOM
Tank collar will not inflate.
MALFUNCTION
Check that inflation valve (2) on tank collar (3) is open.
CORRECTIVE ACTION
Open inflation valve by turning the center part of the inflation
valve (2) clockwise (to the right), as stenciled on the tank collar
(3).
Model WT2008: Check that deflation valve is fully closed.
CORRECTIVE ACTION
Close deflation valve.
Check that automotive valve (1) is not damaged.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check hand pump assembly (9) for damage.
CORRECTIVE ACTION
Replace preformed packing (Item 2, WP 0033 00).
Check foot bellows on Models 91038 and WT2008 for damage.
CORRECTIVE ACTION
Replace foot bellows if required.
Check inflation valve (2) for damage.
|