Figure 41. Suction Hose Disconnected.
Wall Supports.

OPERATOR AND FIELD MAINTENANCE MANUAL FOR TANK UNIT, FUEL DISPENSING, TRAILER MOUNTING: FUEL DISTRIBUTION SYSTEM
Page Navigation
  47    48    49    50    51  52  53    54    55    56    57  
img
0005
TM 10-4930-369-13&P
Figure 43. Dust Plugs and Caps.
11. Remove any spilled fuel from the spill containment system IAW local SOP.
WARNING
Heavy objects need a minimum of two personnel to lift them. Failure to comply may result in
injury to personnel.
There are pinch points and sharp edges on some FDS components. Extreme care must be
used when moving FDS components. Failure to keep hands clear of pinch points may result in
crushed/severed ingers or similar injury to personnel.
12. Remove dunnage supporting FDS, if present.
13. Remove three supports (Figure 44, Item 2) from the pockets (Figure 44, Item 1) in one short wall. Lower
the wall.