TM 10-4930-246-13&P
5-4.
BODY ASSEMBLY REPAIR. - continued
b.
Repair Repair is by replacement of defective or damaged components.
Dry cleaning solvent used to clean parts is potentially dangerous to personnel and
property. Do not usenear open flame or excessive heat. Use in well ventilated area.
(1) Wash all metal parts with dry cleaning solvent.
(2) Dry thoroughly with clean, lint free cloth.
(3)
Be sure that continuity clip hole is clean and free of all debris.
(4)
Inspect all metal parts for dings, gouges, abrasion, etc.
c.
Assembly (Seefigure 5-1.)
NOTE
A light coat of petrolatum can be applied to all gaskets, springs, and O-rings to ease
assembly.
(1) Insert crank pin (27) through link (23) and plate (24). Install nut (26) and tighten to align slots in nut with
hole in crank pin and install new cotter pin (25).
(2) Slip link (23) into slot in shaft (10) and securewith dowel pin (22),
(3) Insert the above subassembly through the inlet end of the body (6). Be sure that the shaft (10) is inserted
into the body's axial guide bore far enough that the bore contains the dowel pin (22).
NOTE
Orientation of plate must be same as observed during disassembly.
(4) Install new backupring (21) andnew seal(20) on lever (7).
(5) Installlever(7).
Correct Alinement of plate and lever is critical to proper operation of the nozzle.
Aline plate and lever before installing socket head screws.
(6)
Aline plate (24) to lever (7) per figure 5-3 andsecurewith four socket headscrews (19).
(7) Install O-ring (17)into body(6).
5-6
|