TM 10-4930-238-12&P
4-21. ADAPTER, WATER DETECTOR.
This task consists of:
a. Removal
b. Inspection
c. Cleaning
d. Repair
e. Disassembly
f. Reassembly
g. Installation
INITIAL SETUP:
Tools Required:
Tool Kit, General Mechanics, Appendix B , Item 3
Materials Requ ired:
Cleaning Solvent (Item 1, Appendix E)
Cloth, Lint-Free (Item 3, Appendix E)
Gaskets, P/N MS27030-6
Sealing Compound (Item 2, Appendix E)
Equipment Conditions:
Forward Area Refueling Equipment shutdown per para. 2-6 b.
General Safety lnstructions:
Do not smoke or use an open flame in vicinity of the Forward
Equipment. Failure to comply may result in personnel injury.
Area Refueling
a.
Removal. (Refer to Figure 4-20.)
(1)
Pull upon camlock levers and remove suction hose assembly (1),
(2)
Pull upon camlock levers and remove adapter (2) from filter/separator (3).
Figure 4-20. Water Detector Adapter, Removal/lnstallation.
431
|