f. Reassembly
TM 10-4930-238-12&P
4-20. WYE FITTING ASSEMBLY - Continued
e.
Disassembly. (Refer to Figure 4-19.)
(1)
Disconnect chain (1) and remove two dust caps (2) and two gaskets (3). Discard gasket.
(2)
Disconnect chain (4) and remove dust plug (5) and gasket (6) from wye fitting (7)
Figure 4-19. Wye Fitting Assembly, Disassembly/Reassembly.
(1)
Refer to Figure 4-19 and install new gasket (6) and dust plug (5) on wye fitting (7). Connect chain
(4).
(2)
Install two new gaskets (3) and two dust caps (2). Connect two chains (1).
g.
Installation.
(1)
Refer to Figure 4-18 and position wye fitting (2) on suction hose assembly (3) and secure by
pushing down on camlock levers.
(2)
Install two discharge hose assemblies (1) and secure by pushing down on camlock levers.
430
|