b. Cleaning.
TM 10-4930-238-12&P
4-17. ADAPTER ASSEMBLY-Continued.
Cleaning solvent is toxic and flammable. Use only in a well-ventilated area.
Avoid prolonged breathing of fumes. Keep solvent away from flames. Do not
use in excessive amounts. Avoid skin contact.
(1) Clean adapter assembly with cleaning solvent.
(2) AIIow to dry.
c.
Inspect ion.
(1) Inspect adapter assembly for missing dust plug or cap.
(2)
Inspect adapter assembly for damaged or missing camlock levers.
d. Repair. Repair is limited to replacing defective parts.
e.
Disasse mbly. (Refer to Figure 4-15.)
(1) Disconnect hook (1) and remove dust plug (2) and gasket (3), Discard gasket.
(2) Remove dust cap (4) and gasket (5) from reducer (6). Discard gasket.
Figure 4-15. Adapter Assembly, Disassembly/Reassembly.
4-24
|