TM 10-4930-238-12&P
f.
Reassembly.
(1)
Refer to Figure 4-15 and install new gasket (5) and dust cap (4).
(2)
Install new gasket (3) and dust plug (2).
(3) Connect hook (1) to camlock lever.
g.
Installation.
(1)
Refer to Figure 4-14 and position adapter assembly (2) on fuel source and secure by pushing
down on camlock levers.
(2)
Install suction hose assembly (1) and secure by pushing down on camlock levers.
4-18. ADAPTER, NOZZLE.
This task consists of:
a. Inspection
b. Cleaning
c. Removal
d. Installation
INITIAL SETUP:
Tools Required:
Tool Kit, General Mechanic's Appendix B, Item 3
Materials Required:
Cleaning Solvent (Item 1, Appendix E)
Cloth, Lint-Free (Item 3, Appendix E)
Equipment Conditions:
Forward Area Refueling Equipment shutdown per para. 2-8 b.
General Safety Instructions:
Do not smoke or use an open flame in vicinity of the Forward Area Refueling
Equipment. Failure to comply may result in personnel injury.
a.
Inspect ion.
(1)
Inspect adapter for leaks.
(2)
Inspect adapter for missing or damaged end cover.