TM 10-4930-229-12&P
4-19. Adapter, Water Detector Kit (cont).
(2) Reassembly.
(a) Apply sealing compound to threads and install male coupling half (9) and female coupling half (8) on
nipple (10).
(b) Apply sealing compound to threads and install probe assembly (7). Ensure beveled side of probe
faces female coupling half (8).
(c) Install new gasket (6) and dust cap (5). Secure with camlock levers (4).
(d) Install new gasket (3) and dust plug (2). Secure with camlock levers (1).
Figure 4-13. Water Detector Kit Adapter, Disassembly/Assembly.
4-31
|