TM 10-4320-347-13&P 4.7.  SLAVE CABLE REPAIR AND REPLACEMENT  - (Continued.) Figure 4-5.  Slave Cable Repair. CAUTION Improper   installation   of   wiring   can   damage   the   pump   or   cause   the   pumping assembly to fail to operate.  Be sure to properly connect the positive and negative wires or pump will rotate in wrong direction and will not pump fluid. NOTE Wires must be traced to receptacle to determine which wire is positive or negative. (4)   Twist black motor wire lead (6) together with ( - ) negative lead of slave cable wire (8).  Install wire nut (5). (5)   Twist red motor wire lead (6) together with ( + ) positive lead of slave cable wire (8).  Install wire nut (5). (6)   Stuff wiring into junction box and install junction box cover (3), four bolts (1), and four washers (2) onto junction box (4). 4-10