TM 10-4320-324-14
Section III. OPERATION UNDER USUAL CONDITIONS
2-5. Assembly and Preparation for Use.
a.
Upon reaching the operating area where pumping assembly is to be used, prepare the equipment for use as follows:
(1)
Position pumping assembly in such a manner that connections of where liquid is to be pumped from will connect
with fittings on suction valve. Locate pumping assembly as close as possible to liquid source. Keep suction lift
as low as possible.
(2)
Be sure site is as nearly level as possible; clean site of rocks and vegetation. Be sure surface is firm enough to
support pumping assembly. If it is necessary to place the unit on soft ground, arrange a foundation of planking,
logs, or any other suitable material.
(3)
Be sure all sides of pumping assembly, and all fittings and controls are easily accessible.
(4)
Remove pins (1 and 2) to extend trailer support legs (3) as far as possible.
(5)
Reinstall pins (1 and 2) to secure trailer support legs (3).
(6)
Release pintle (4) and disconnect pumping assembly from towing vehicle (5).
(7)
Position pumping assembly such that frame support legs (3) support forward section of pumping assembly.
2-9
|