TM 10-4320-324-14 4-40.  Shutdown Solenoid Replacement (CONT). c. Cleaning/Inspection. WARNING Dry cleaning solvent P-D-680 is toxic and flammable.  Wear protective goggles and gloves and use only in a well ventilated area.  Avoid contact with skin, eyes, and clothes and don't breathe vapor.  Do not use near  open  flame  or  excessive  heat.    The  flash  point  is  1000F-1380F  (380-500C).    If  you  become  dizzy while using cleaning solvent, get fresh air immediately and get medical aid.  If contact with eyes is made, wash your eyes with water and get medical aid immediately. (1)    Clean all metal surfaces with cloth and solvent. (2)    Wipe rubber boot (13) with clean cloth. (3) Inspect electrical terminals for cracks, corrosion, and looseness. (4)    Inspect solenoid housing and linkage for cracks or any other damage. (5)    Repair by replacing defective parts. 4-126