4-40. Shutdown Solenoid Replacement (CONT).
c.
Cleaning/Inspection.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use only
in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapor. Do not use
near open flame or excessive heat. The flash point is 1000F-1380F (380-500C). If you become dizzy
while using cleaning solvent, get fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
(1) Clean all metal surfaces with cloth and solvent.
(2) Wipe rubber boot (13) with clean cloth.
(3)
Inspect electrical terminals for cracks, corrosion, and looseness.
(4) Inspect solenoid housing and linkage for cracks or any other damage.
(5) Repair by replacing defective parts.
4-126
|