TM 10-4320-324-14
b. Removal.
CAUTION
Solenoid linkage is factory set. Do not adjust at field level.
(1) Remove two screws (1), two flat washers (2), and filter support (3).
NOTE
Tag wires before removal.
(2) Disconnect three lead wires (4).
(3) Remove pin (5).
(4) Remove nut (6), lockwasher (7), and washer (8).
(5) Remove two mounting bolts (9), two lockwashers (10), two flat washers (11), and shutdown solenoid (12).
4-125
|