TM10-4320-324-14
4-40. Shutdown Solenoid Replacement.
This task covers:
a. Testing
c. Cleaning/Inspection
e. Follow-on Maintenance
b.
Removal
d. Installation
INITIAL SETUP:
Tools
Equipment Condition
Tool kit, general mechanics: automotive, item 32,
Engine shut down (para 2-7).
section III, appendix B
Fuel line from feed pump and injection pump
Multimeter, item 33, section III, appendix B
removed (para 4-41).
Fuel filter removed (para 4-43).
Materials/Parts
Oil filter removed (para 4-52).
Cloth, lint free, item 3, appendix E
Oil line removed (para 4-56).
Solvent P-D-680, dry cleaning: item 15,
appendix E
General Safety Instructions
Lockwasher (5) SE-2366
Wear personal protective equipment
when using cleaning solvent.
a.
Testing.
(1) Connect 12-volt test lamp to auxiliary terminal
(1) and ground terminal (2).
CAUTION
Release oil pressure bypass switch within 30
seconds
if
voltage
is
not
indicated
(by
illumination of light) at the auxiliary terminal.
Oil pressure sending unit may burn out.
(2) Depress oil pressure bypass switch and monitor
solenoid
rod
retraction
and
test
lamp
illumination.
(3)
If the solenoid rod does not retract or test lamp
does not illuminate, replace shutdown solenoid.
4-124
|