Page Title: Figure 6-25. Checking flywheel housing and flywheel for runout.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

MEC 4320-240-15/6-25
Figure 6-25. Checking flywheel housing and flywheel for runout.
(3) Check the clearance between the crankshaft
(6)  An alternate method of checking bearing
bearing journals and bearings with Plastigage as
clearance is as follows:
directed in paragraph 6-16d.
(a) Oil bearing and bearing journal with engine
(4) Clearance must be between .0024 and .0044
oil.
inch. If the clearance is not within these limits, replace
the bearings and recheck the clearance.
(b) Position a strip of 0.0044 inch feeler gauge,
inch long, on the bearing cap.
(5)
Check the remaining bearing-to-bearing
journal clearances and replace bearings as necessary.
(c) Install the cap on the block; secure with the
screws and lockwashers. Tighten the screws to 10-12 ft-
lbs. of torque.