TM 9-2330-398-24
3-41. EMERGENCY VALVE REPAIR (continued).
c. CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-80 is toxic and flammable. Always wear protective
goggles and gloves, and use only In a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and do not breathe vapors. Do not use near flame or
excessive heat
1.Clean emergency valve and all metal parts with drycleaning solvent and rag. Dry thoroughly.
2.Inspect emergency valve for damage and wear. Replace emergency valve if damaged.
d. ASSEMBLY
1.Install cam (29) and stem (28) in body (20).
2.Install new O-ring (25), two new preformed packings (27), and stuffing box nut (26) on stem (28).
3.Install lever (23) on stem (28), and tighten screw (22) and nut (24).
3-122
|