TM 9-2330-398-24
3-31. FILTER SEPARATOR REPLACEMENT (continued).
NOTE
When installing coupling, lubricate gasket with petrolatum.
5.
Install two couplings (8) and new seals (6) on inlet and outlet lines (5) at filter separator (1) with two screws (7).
Tighten screws (7) between 95 and 105 Ib-ft (129 and 142 N.m).
6.
Install two drain plugs (3) in filter separator (1),
7.
Close manual drain valve N (4), and open valve
M (2).
FOLLOW-ON MAINTENANCE:
Disconnect ground (refer to TM 9-2330-398-10).
3-99
|