TM 9-2330-398-24
3-20. FUEL METERING PUMP REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
Initial Setup:
Tools/Test Equipment
Preformed packing (Item 140, Appendix F)
General mechanic's tool kit (Item 4, Appendix B)
Equipment Conditions:
Material/Parts:
Semitrailer uncoupled (refer to TM 9-2330-398-10).
Cap and plug set (Item 3, Appendix C)
Semitrailer bonded and grounded (refer to
Fuel oil, diesel (Item 15, Appendix C)
TM 9-2330-398-10).
Drycleaning solvent (Item 12, Appendix C)
Negative battery cable disconnected (para 2-33).
Petrolatum (Item 24, Appendix C)
Top air housing cover removed (para 3-26).
Rag (Item 25, Appendix C)
Fuel injection lines removed (para 3-21).
Lockwasher (4) (Item 113, Appendix F)
a. REMOVAL
CAUTION
All fuel connection must be plugged or capped to prevent contamination and equipment damage.
1.
Remove two nuts (3) and governor linkage (2)
from fuel metering pump (1), and governor
control arm (4).
3-58
|