TM 9-2330-398-24
2-128. PRECHECK CONTROL TUBING ASSEMBLY REPLACEMENT (continued).
9.
Disconnect tubing assembly (14) from adapter (15) on manifold (16), and remove tubing assembly (14) from
semitrailer.
10.
Disconnect tubing assembly (18) from elbow (21) on float valve (20), and remove tubing assembly (18) from
semitrailer. Remove elbow (21) from float valve (20).
11.
Remove two adapters (15 and 17) and manifold (16) from tubing assembly (18), 12.
Disconnect
tubing
assembly (13) from adapter (25) on manifold (24).
13.
Disconnect tubing assembly (22) from adapter (19) on float valve(20), and remove tubing assembly (20) from
semitrailer. Remove adapter (19) from float valve (20).
14.
Remove two adapters (23 and 25) and manifold (24) from tubing assembly (22).
b.
INSTALLATION
1.
Install two adapters (23 and 25) and manifold (24) on tubing assembly (22).
2.
Install adapter (19) on float valve (20), and connect tubing assembly (22) to adapter (19).
3.
Connect tubing assembly (13) to adapter (25) on manifold (24).
4.
Install two adapters (15 and 17) and manifold (16) on tubing assembly (18).
5.
Install elbow (21) on float valve (20), and connect tubing assembly (18) to elbow (21).
6.
Connect tubing assembly (14) to adapter (15) on manifold (16).
2-283
|