TM 9-2330-398-24
2-123. FLOW CONTROL VALVE AND FLANGE ASSEMBLY REPLACEMENT (continued).
NOTE
Lubricate seal with petrolatum prior to installation.
11.
Install flow control valve (8) and new seal (17) and coupling (2) on flange assembly (1) with two nuts (3).
12.
Install new seal (11) and coupling (9) on piping (12) and flow control valve (8) with two nuts (10).
13.
Connect line (14) to tee (13), and connect line (15) to elbow (7).
14.
Connect line (4) to tee (16) and connect line (6) to tee (5).
FOLLOW-ON MAINTENANCE:
Connect negative battery cable (para 2-33).
2-270
|