TM 9-2330-398-24
2-123. FLOW CONTROL VALVE AND FLANGE ASSEMBLY REPLACEMENT (continued).
2.
Disconnect line (15) from elbow (7), and disconnect line (14) from tee (13).
3.
Remove two nuts (3) and coupling (2) and seal (17) from flange assembly (1) and flow control valve (8). Discard
seal.
4.
Remove two nuts (10) and coupling (9), seal (11), and flow control valve (8) from piping (12). Discard seal.
5.
Disconnect line (15) from adapter (18).
6.
Remove elbow (7), tee (5), adapter (24), tee (16), and check valve (23) from flow control valve (8).
7.
Remove adapter (18) from tee (21).
8.
Remove drain cock (20), tee (13), valve (19), tee (21) and adapter (22) from flow control valve (8).
9.
Remove elbow (7 from tee (5).
2-267
|