TM 9-2330-398-24
2-77.
STATIC REEL AND ELECTRICAL CUP REPLACEMENT.
This Task Covers:
a.
Removal
b.
Installation
Initial Setup:
Tools/Test Equipment:
Equipment Conditions:
General mechanic's tool kit (Item 4, Appendix B)
Semitrailer uncoupled (refer to TM 9-2330-398-10).
Semitrailer bonded and grounded (refer to
Materials/Parts:
TM 9-2330-398-10).
Lockwasher (4) (Item 99, Appendix F)
Self-locking nut (2) (Item 172, Appendix F)
a.
REMOVAL
NOTE
Removal of static reels and electrical clips from piping cabinet and hose reel cabinet is the same.
One is shown here.
1. Remove two screws (2), fourwashers (3), two self-locking nuts (4), and static reel (1) from cabinet (5). Discard
lockwashers and self-locking nuts.
2. Remove screw (7), nut (9), and clip (8) from cable (6).
b.
INSTALLATION
1. Install static reel (1) on cabinet (5) with two screws (2), four new lockwashers (3), and two new self-locking nuts
(4).
2. Install electrical dip (8) on cable (6) with screw (7) and nut (9).
FOLLOW-ON MAINTENANCE:
Disconnect ground (refer to TM 9-2330-398-10).
2-172
|