TM 9-2330-398-24 2-74. FILL GAGE STORAGE TUBE CAP REPLACEMENT. This Task Covers: a. Removal b. Installation Initial Setup: Tools/Test Equipment: Equipment Conditions: •   General mechanic's tool kit (Item 4, Appendix B) •   Semitrailer uncoupled (refer to TM 9-2330-398-10). •   Semitrailer bonded and grounded (refer to TM 9-2330-398-10). a. REMOVAL WARNING Ladder has narrow tread.  Use care when climbing. 1.    Remove cap (2) from fill gage storage tube (1). 2.    Remove two S-hooks (3), spring (5), and chain (4) from fill gage storage tube (1) and cap (2). b. INSTALLATION 1.    Install chain (4) and spring (5) on fill gage storage tube (1) and cap (2) with two S-hooks (3). 2.    Install cap (2) in place on fill gage storage tube (1). FOLLOW-ON MAINTENANCE: •   Disconnect ground (refer to TM 9-2330-398-10). 2-168