TM 9-2330-398-24
2-57.
AIR LINE TUBING AND FITTINGS REPLACEMENT (continued).
b.
INSTALLATION
1.
Apply Teflon antiseize tape to fitting (6), and install fitting (6) on air reservoir (7).
NOTE
Air line tubing is stocked in bulk lengths. Measure original air line tubing and cut new air line
tubing to same length. Trim ends of air line tubing to get a smooth, square cut.
2.
Install nut (4), compression sleeve (8), and insert (5) on both ends of air line tubing (3), and install air line tubing
(3) on fitting (6).
3.
Pull air line tubing (3) through grommets (1) and secure with clips (2).
NOTE
Semitrailer must be coupled to prime mover or air source to perform test. Refer to TM 9-2330-398-
10.
c.
TEST
Apply soapy water to ends of new air line tubing (3) and check for leaks. If leaks are detected, replace tubing.
FOLLOW-ON MAINTENANCE:
Disconnect ground (refer to TM 9-2330-398-10).
2-143
|