TM 9-2330-272-14
4-100. FLOW CONTROL VALVE REPLACEMENT.
This Task Covers: Replacement
Initial Setup:
Equipment Conditions:
Materials/Parts:
Tank purged (para 4-64).
Rags (Item 14, Appendix E)
All manual valves closed.
Two gaskets
Tools/Test Equipment:
Eight Iockwashers
General mechanics tool kit
Common no. 1 shop set
REPLACEMENT
NOTE
A drain pan should be used to catch any draining fluid. Ensure that all spills are cleaned
up.
1.
Disconnect tube (3) from flow control valve (4).
2.
Remove eight nuts (7), Iockwashers (6), screws (5), two gaskets (2), and flow control valve (4) from two tubes
(1). Discard Iockwashers and gaskets.
3.
4.
Install two new gaskets (2) and flow control valve (4) on two tubes (1) with eight screws (5), new Iockwashers (6),
and nuts (7).
Connect tube (3) to flow control valve (4).
4-220
|