TM 55-2915-335-30&P
2-16. MOTOR COVER - lNSPECT/REPLACE (Cont)
2-16
2. CLEANING
Compressed air aimed at the skin can cause serious injury or death.
Wear goggles and never use over 30 psi (207 kPa) of compressed air
for cleaning.
Cleaning solvent can be hazardous to your health. Use solvent only
in well ventilated areas. Avoid breathing solvent vapors. Do not use
solvent near an open flame or other source of high heat. Always wear
gloves, apron, and goggles when using cleaning solvent. Store solvent
in approved metal container only.
a. If inside of cover looks dark gray or black, scrub with soft bristled brush in cleaning solvent.
Do not use drill bits to open clogged ports in motor cover. Drilling
may alter explosion-proof design of the cartridge and cause serious
injury or death of personnel.
b. Clean dirt or sludge from fluid ports in cover with a fine lockwire, 0.020 inch (0,508 mm) Dia. maximum, and
cleaning solvent. If dirt cannot be removed with wire, replace cover. Dry cover with compressed air, 30 psi (207
kPa) maximum.
GO TO NEXT PAGE
2-45
|